How To Exam?

a knowledge trading engine...


Thapar University 2006 M.E Earthquake Analysis & Design of Structures - Question Paper

Friday, 19 April 2013 03:05Web



Thapar Institute of Engineering & Technology
M.E. (2nd Year)
Final Term exam
ST009 (Earthquake Analysis & Design of Structures )



THAPAR INSTITUTE OF ENGINEERING AND TECHNOLOGY, PATIALA

End Semester Test (7/12/2006)

Earthquake Analysis and Design of Structures (ST-009)

Note: Use of SP-16 and IS- 1893-2002 is allowed.

Attempt any five questions

Max Mks: 90    Duration: 3 Hrs

1. (a)

Explain Reids Elastic Rebound Theoiy of origin of earthquakes.

3

(b)

Discuss different types of seismic waves.

5

(c)

What is Response Spectra and give its formulation for SDOF initially at rest.

5

(<J)

Explain the concept of Seismic Demand Diagrams.

5

2. (a)

Explain Soft Storey and how it should be accounted for in analysis and design.

6

(b)

Explain the major damages experienced by R.C buildings during Bhuj earthquake and list the lessons learnt from the same.

12

(a)    With reference to performance of RC buildings, explain

(i)    Diaphragm Discontinuity

(ii)    Re-Entrant Comers

(iii)    Vertical and Torsion irregularities

(b)    Explain the modeling of the following :

(i)    Floor diaphragms

(ii)    Soil and foundation models

(a)    Explain the following:    9

(i)    Non-Conventional Seismic Retrofitting Strategies

(ii)    Local Retrofitting Methods.

(b)    Discuss the components of Seismic Evaluation Methodology and how are the damages 9 in building components identified during the process.

Consider the data given below for a three storied RC building and calculate the lateral force distribution using Response Spectrum Method (SRSS). Neglect the stiffness of infill walls.

18


Type of structure

SMRF

Seismic Zone

III

Floor Height

3.5 m

Infill wall

150mm thick

Materials

M20 and Fe415

Imposed Load

3.5 kNW

Size of columns

300mm X 450mm

Size of beams

250mm X 350mm

Depth of slab

120mm

Specific weight of RCC

25kN/m"

Specific weight of infill

20 kN/m'1

Type of soil

Rocky

Given:

(i) Mass matrix of the lumped model as 30 tons, 60 tons and 60 tons for the top, middle and bottom floor

(ii) Eigen Vector as 0r {-0.033, -0.061, -0.08}, 02={O.O795, 0.064, -0.03} 03= {0.081,-0,054, -0.045}.

Plan of the building is as shown below:

3 X 3 =9 m

5X3= 15 m


Plan of Building

6.    Design and Detail the Flexural Member 1, Interior Column 2 and the corresponding 18

Beam- Column Joint for the structure shown above subjected to the following design moments and loads according to IS-13920-1993.

Show the detailing clearly.

Beam 1- Hogging moment 250 kN-m, Sagging Moment 150 kN-m,

Maximum S.F= 150 kN Column 2- Moment = 350 kN-m Axial load = 500 kN

Note: Students can see their evaluated sheets on 12th Dec, 2006 at 10:00 am in the room of the concerned faculty.







Attachment:

( 0 Votes )

Add comment


Security code
Refresh

Earning:   Approval pending.
You are here: PAPER Thapar University 2006 M.E Earthquake Analysis & Design of Structures - Question Paper