Anna University Chennai 2009-5th Sem B.Arch Architecture -AD--Model - Question Paper
attaching the Architectural design model ques. paper for V semester B.Arch
MODEL QUESTION PAPER
B.Arch. Degree Examinations
V Semester
AR336 - ARCHITECTURAL DESIGN -V
Duration : 12 Hours. Max. : 100 marks.
First Day = 6 Hours
Second Day=3 +3 Hours.
Instruction to the candidates
1. Answer any ONE Question.
2. Candidates are to submit the concept at the end of the first day and will not be return to the candidates.
3. Candidates are to retain a copy in the examination hall for next days reference.
4. Deviation from the concept will not be permitted.
5. Drawing sheets, tracing sheets and butter paper will be provided for the examinations.
6. Reference books, standards and design manual are not permitted in the Examination hall.
7. General drawing requirement applicable for both question A or B.
First Day
Preliminary drawings of concept any scale
Second Day
Site plan 1:200 / 1:500
Detail floor plan / plans 1:100
Min.1 nos. critical section and 1:100
Min.1 nos. front elevation 1:100
Viewsinternal or external explaining the design.
Answer any ONE question
QUESTION A SHOPPING COMPLEX
Introduction A shopping complex is to be constructed on a busy shopping area of Chennai city classified as commercial use zone by CMDA. The building is to respond to the modern expression of commercial built form along with the user requirement like changing needs of shop owner (in terms of display technique, interior details and layout). Also to consider the behavioral pattern and shopping preference of the consumers. Apart from shopping activities, support functions like restaurant and play areas and service area to be provided. The complex also is to respond to the structural system and service integrations.
Site The site of 70m x 50m is located on a road junction, with North South axis lying on the longer side of the site. The Western end of the site faces 45m wide road and Southern end of the site faces 30m wide road.
Guidelines The proposed building is situated in the Commercial use zone as per the CMDA classification the guidelines as per the CMDA development control rules are as follows
Maximum FSI 1.5
Maximum plot coverage 65 percent
Minimum plot frontage 7.0m
Maximum height One and half times the width other abutting road provided that the height may exceed to the extent of one metre for every 30cm by which the building is set back from the street or 15 metres whichever is less.
Minimum Front setback Abutting road width set back
Above 30.0m 6.0
Above 15m but less 4.5m
Than 30.0m
Minimum side setback th height of the building subject to a minimum of 2m of either side.
Minimum rear setback th height of the building subject to a minimum of 2m.
Packing standards
Floor area upto 50sq.m = Nil
Floor area upto 50sq.m = 1 car space below 100 sq.m
For every additional = 1 car space 50 sq.m or part there of exceeding 100 sq.m
Parking dimension: 5m x 2.5m per parking bay with min. one way drive way of 3.5m and min. two way drive way of 7.2m
Design requirement
Areas mentioned are in sq.m and are approximate. Where area is not given, candidates are expected to work out areas themselves on the bases of the usage pattern
Shopstextile shop, showrooms etc. 40% of total building area
Impulse goods 20% of building area
Essential commodities 25% of total building area
Restaurant, play area 10% of total building area
Gallery, public spaces 5% of total building area.
Note :
Shopping room size range from 1530 sq.m
Provision of toilets, common spaces and fire escape stairs to follow the norms and std.
Services:
A.C Plant room 100sq.m
Pump room 10sq.m
Electrical room 50sq.m
Electrical service room 20sq.m
Generator room 50sq.m
BMS room 15sq.m
Security room 15sq.m.
Fire control room 20sq.m
Maintenance room 50sq.m
Caretakers quarters 40sq.m
REFER general drawing requirement in page 1
OR
QUESTION - B CLUB HOUSE DESIGN
Introduction Man is the nucleus to the society-taking role in various stages, various sections with vigor and passion. And for him at times it is inevitable to take a break and indulge in leisure activities to satisfy his basic needs of relaxation, recognition in society and recuperate. Hence the clubhouse design is to inculcate the appropriate ambience with qualitative aesthetic environment to make the user relax both mentally physically.
Site The 13acre site for Clubhouse is located at contour layout in a hill station. The eastern end of the site overlooks a valley with a narrow stream at the lower part of the contour and the southern part of the site has range of hills banking the site line. Consideration to site in terms of vegetation, climate topography, drainage pattern etc. are to be observed in design of the Clubhouse. Also various vantage points in term of landscape elements, aesthestic viewpoint and visibility can be exploited to make the design more contextual and realistic.
Area requirements
1. Grand lounge:
- Reception 10sq.m.
- Display area 5sq.m
- Seating 40sq.m for 20 no.
- Common toilet male and female toilets each 20sq.m
2. Administration
Managers room 25sq.m with toilet
Office 30sq.m with common toilet
Record room 15sq.m
Meeting room / conference room for 30 no. 80sq.m
Business center (with secretary facility) 30sq.m
House keeping 20sq.m
3. Library
Librarian room 10sq.m
Book issue counter / catalogue section. 15sq.m
Magazine / reference section 15sq.m
Reading space for 15 nos. 30sq.m
Stack room 35sq.m
Store room 15sq.m
4. Party Hall
Hall for 250 nos. 500sq.m with separate toilets
Prefunctional spaces 100sq.m
Store room 20sq.m
5. Restaurant
Dining for 100 persons 300sq.m
Coffee shop for 40 persons 60sq.m
Bar for persons 30sq.m
Kitchen and pantry area 100sq.m
Store room 20sq.m
6. Indoor Games
Shuttle / Badminton 2 courts
Table tennis 2 nos.
Billiards / Snooker 4 nos.
Group / table games 10 nos.
7. Health club / fitness center 600sq.m
(Aerobics, sauna, gym etc.)
8. Outdoor games
.
Tennis 600sq.m (2 nos.)
Children play area Assume suitable area
Jogging track Assume suitable area
9. Swimming pool
- Reception / Waiting area 30sq.m
- Pool area 1000sq.m
- Locker room, toilet, changing room 40sq.m
- Machine room 15sq.m
10. Open air theatre For 500 persons with toilets
for each.
11. Service:
- Maintenance office 15sq.m
- Laundry 40sq.m with drying yard
- Generator room 25sq.m
- Boiler room 25sq.m
- Electrical room 15sq.m
- Workshop / carpentry 25sq.m
- Any other facilities required to be included Assume suitable area
REFER general drawing requirement in page 1.
Earning: Approval pending. |