Gujarat University 2007 B.E Civil Engineering Design of Concrete Structures - Question Paper

Monday, 13 May 2013 11:55Web



1/203    A    Candidates Scat No .

GUJARAT UNIVERSITY B.E. Sem. VII (Civil) Examination Design of Concrete Structures Saturday, 29th December, 20Q7|    |Time : 4 Hours

Max, Marks : 100

Instructions : (1) Attempt all questions.

(2)    Answer to the two sections must be written in separate answer books,

(3)    Assume suitable data if required.

(4)    Figures to the right indicate full marks.

(5)    Use of IS:456,1S:875, SP:16, IS: 1893 is permissible. Reference to clauses, charts, tables, etc should be mentioned.

(6)    Assume suitable grade of material if not given.

SECTION - 1

1(a) Explain the significance of stability checks for retaining walls and briefly explain the 5 steps of stability checks.

(b) A counterfort retaining wall has to retain level earth of 7m height above ground level. 30 The counterforts of 400nim width are provided at 3.3m c/c. Take SBC=170kN/nr, angle of internal friction=30 degree, friction coefficient between soil and concrete=0.5 and unit weight of soil= 16 kN/m3. Using Mio grade of concrete and Fe 415 grade of steel, calculate the depth of foundation, propose cross section of retaining wall. Design and detail vertical slab and counterfort.

OR

Draw a typical floor plan of a .small commercial building having floor height 3.3m.

1    (a) Draw proper structural layout, designate all structural members and draw load 10

distribution diagram.

(b)    Design and detail any one typical continuous beam. Use substitute frame for analysis. 15

(c)    Design and detail two different types of slabs.    10

2    A mulu-storeyed building (GF parking+ 7 upper floors) is 24m x 24m in plan. The 15 building is situated on Ashram Road of Ahniedabad. Taking suitable grid in plan plot

wind pressure and force distribution diagrams along the height of building as per lS:875(Part-3).

SECTION-Ii

3    (a) Fix the basic dimensions of suitable container of elevated water tanks to store 6 lacs 30

liters water. Design and detail all structural components of the container.

(b) Illustrate various supporting systems to support elevated storage reservoir. Explain 5 briefly about various design forces for supporting system.

OR

3    (a) Discuss use and significance of RC portal frame    5

(b)    A fixed based portal frame having width 10m and height 7m is analysed considering 25

1 beam / 1 t.<iunui = 2.75 and final factored moment obtained at fix base * 75 kN.nn at Beam-column joint- -150 kN.m and ai mid of beam - 250 kN.m. Design & detail beam and column of the portal.

(c)    Draw typical detail of reinforcement of fooling to be provided for above portal frame. 5

4    A combined footing i> carrying two loads of 800kN and 900kN spaced at 3.8m. Propose 15 the foundation plan if (i) width of fooling is restricted to 2.2m and(ii) No restriction on width. Taking cross section of both columns 0.3m x 0.3m, design & detail slab type footing for any one case.